Command Matrix for the WX6000 Series
Table 4-2 Command matrix for the WX6000 series
Volume Module Command WX6103 LSQM1WCMB0 LSBM1WCM2A0 LSRM1WCM2A1
Login commands
telnet ipv6
Yes Yes No Yes
display
user-interface
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 6.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
free user-interface
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 6.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
send
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 6.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
User Interface
Commands
user-interface
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 6.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
AUX, console and
VTY user interfaces
are supported.
When number is an
absolute index, the
value ranges from 0
to 12.
configuration
encrypt
No No No No
Fundamentals
Command Reference
File management
configuration
commands
ftp ipv6
Yes Yes No Yes